In situ assessment of superficial moisture condition in façades of historic building using non-destructive techniques
Flores Sasso, Virginia, Ruiz Valero, Letzai and Prieto Vicioso, Esteban (2019) In situ assessment of superficial moisture condition in façades of historic building using non-destructive techniques. Case Studies in Construction Materials (10). pp. 1-14. ISSN 2214-5095 [Article]
|
PDF
In situs assessment of superficial moisture, VFS.pdf Available under License Creative Commons Attribution Non-commercial No Derivatives. Download (6MB) | Preview |
Abstract (in English)
In historic building the water resistance capacity of their external materials is a relevant property that must be known, because the materials play a fundamental role in the interaction with the external environment. The aim of this research is to evaluate in situ the superficial moisture condition in facades using non-destructive techniques (NDT). Two different moisture measuring NDT was used: Infrared Thermography (IRT) and Electrical Resistance Measuring (ERM); in addition, the Air Temperature and Relative Humidity were measured. The IRT identifies the temperature of the material and offers a thermal image with different temperatures that is interpreted as moisture area. A Moisture Mapping is obtained with ERM, which represents the moisture conditions in the facades. Both techniques give an idea of moisture areas. The results of both graphics shows that the most humid areas correspond to the same areas that obtain by IRT and ERM. In conclusion, using these two NDT at the same time it is possible to acquire usually a quick, qualitative, precise and economic results of: moisture areas in situ, important data to survey and the assessment the historic building for monitoring or preservation project.
Item Type: | Article |
---|---|
Authors: | Authors Email Flores Sasso, Virginia vfloressasso@gmail.com Ruiz Valero, Letzai l.ruiz@ce.pucmm.edu.do Prieto Vicioso, Esteban eprietovicioso@gmail.com |
Corporate Authors: | Pontificia Universidad Catolica Madre y Maestra; Pontificia Universidad Catolica Madre y Maestra; Universidad Nacional Pedro Henriquez Urena |
Languages: | English |
Keywords: | Built heritage; historic buildings; facades; monitoring; Non-destructive techniques; In situ assessment; Infrared thermography; Electrical Resistance Measuring; Moisture mapping; Moisture condition; case studies; churches; Climate conditions; Environmental conditions; building materials; thermal properties; Dominican Republic |
Subjects: | E.CONSERVATION AND RESTORATION > 03. Monuments E.CONSERVATION AND RESTORATION > 12. Techniques F.SCIENTIFIC TECHNIQUES AND METHODOLOGIES OF CONSERVATION > 06. Analysis of materials F.SCIENTIFIC TECHNIQUES AND METHODOLOGIES OF CONSERVATION > 28. Infra red analysis F.SCIENTIFIC TECHNIQUES AND METHODOLOGIES OF CONSERVATION > 36. Non-Destructive testing G.DETERIORATION > 02. Causes of deterioration G.DETERIORATION > 05. Prevention of deterioration H.HERITAGE TYPOLOGIES > 09. Historic buildings H.HERITAGE TYPOLOGIES > 12. Historic towns and villages P. GEOGRAPHIC AREAS > 01. Americas |
Name of monument, town, site, museum: | Iglesia Parroquial de Santa Barbara; Ciudad Colonial de Santo Domingo; Santa Barbara church, Santo Domingo, Dominican Republic |
National Committee: | Dominican Republic |
Number: | 10 |
ISSN: | 2214-5095 |
Depositing User: | ICOMOS Dominicano |
Date Deposited: | 16 Oct 2019 08:44 |
Last Modified: | 16 Oct 2019 08:44 |
References: | [1] D. Paoletti, D. Ambrosini, S. Sfarra, F. Bisegna, Preventive thermographic diagnosis of historical buildings for consolidation, J. Cult. Herit. 14 (2) (2013) 116–121, doi:http://dx.doi.org/10.1016/j.culher.2012.05.005 ELSEVIER.. [2] M. Tavares, A. Magalhães, M. Veiga, J. Aguiar, - Diagnosis Methods for Coatings of Ancient Buildings. Importance and Applicability of in Situ Tests (in Spanish) (access May 2009) available at, Revista Boletín del Instituto, Andaluz del Patrimonio Histórico, 2005. http://conservarcal.lnec.pt. [3] Ruben Duarte, Ines Flores-Colen, Jorge de Brito, “In situ testing techniques for evaluation of Water penetration in rendered facades - the portable moisture meter and karsten tube”, XII International Conference on Durability of Building Materials and Components (DBMC) (2011). [4] X. Maldague, Theory and Practice of Infrared Technology for Nondestructive Testing, Wiley, New York, NY, USA, 2001. [5] Silvana Fais, Giuseppe Casula, Francesco Cuccuru, Paola Ligas, Maria Giovanna Bianchi, “An innovative methodology for the non-destructive diagnosis of architectural elements of ancient historical buildings”, Sci. Rep. 8 (2018)4334. [6] J.A. Cusidó, M. Devant, J. Riba, Aplicaciones de la termografía infrarroja y la espectrorradiometría en el estudio del deterioro del patrimonio arquitectónico nacional, Informes de la Construcción. 48 (443) (1996), doi:http://dx.doi.org/10.3989/ic.1996.v48.i443.1003. [7] E. Grinzato, V. Vavilov, T. Kauppinen, Quantitative infrared thermography in buildings, Energy Buildings J. 29 (1998) 1–9. [8] E. Grinzato, P.G. Bison, S. Marinetti, Monitoring of ancient buildings by thermal method, J. Cult. Herit. 3 (1) (2002) 21–29, doi:http://dx.doi.org/10.1016/ S1296-2074(02)01159-7 ELSEVIER. [9] E. Grinzato, G. Cadelano, P. Bison, Moisture map by IR thermography, J. Mod. Opt. 57 (18) (2010) 1770–1778. [10] F. Bisegna, D. Ambrosini, D. Paoletti, S. Sfarra, F. Gugliermetti, A qualitative method for combining thermal imprints to emerging weak points ofancient wall structures by passive infrared thermography – a case study, J. Cult. Herit.15 (2) (2013) 199–202, doi:http://dx.doi.org/10.1016/j.culher.2013.03.006 ELSEVIER. [11] G. Arena, M. Rippa, P. Mormile, M. Grilli, M. Paturzo, G. Fatigati, P. Ferraro, Concurrent studies on artworks by digital speckle pattern interferometry and thermographic analysis, Proceedings of the SPIE OPTO International Society for Optics and Photonics (2016) 977107. [12] J. Lerma, M. Cabrelles, C. Portalés, Multitemporal thermal analysis to detect moisture on a building façade, Constr. Build. Mater. 25 (5) (2011) 2190– 2197, doi:http://dx.doi.org/10.1016/j.conbuildmat.2010.10.007 ELSEVIER. [13] C. Rodríguez Liñán, M.J. Morales Conde, P. Rubio de Hita, F. Pérez Gálvez, Inspección mediante técnicas no destructivas de un edificio histórico: Oratorio San Felipe Neri (Cádiz), Informes de la Construcción 63 (521) (2011) 13–22, doi:http://dx.doi.org/10.3989/ic.10.032 eISSN: 1988-3234. [14] E.Z. Kordatos, D.A. Exarchos, C. Stavrakos, A. Moropoulou, T.E. Matikas, Infrared thermographic inspection of murals and characterization of degradation in historic monuments, Constr. Build. Mater. 48 (2013) 1261–1265, doi:http://dx.doi.org/10.1016/j.conbuildmat.2012.06.062 ELSEVIER. [15] G. Kilic, Using advanced NDT for historic buildings: towards an integrated multidisciplinary health assessment strategy, J. Cult. Herit.16 (4) (2015) 526– 535, doi:http://dx.doi.org/10.1016/j.culher.2014.09.010 ELSEVIER. [16] G. Litti, S. Khoshdel, A. Audenaert, J. Braetb, Hygrothermal performance evaluation of traditional brick masonryin historic buildings, Energy Build. 105 (2015) 393–411, doi:http://dx.doi.org/10.1016/j.enbuild.2015.07.049 ELSEVIER. [17] J.C. Pérez-Sánchez, B. Piedecausa-García, Termografía infrarroja aplicada en cúpulas históricas: identificación y análisis de sistemas constructivos, Informes de la Construcción 68 (541) (2016) e129 doi: https://doi.org/10.3989/ic.14.133. [18] A. Hola, Measuring of the moisture content in brick walls of historical buildings – the overview of methods, IOP Conf. Series, Mater. Sci. Eng. 251 (2017) (2017) 012067, doi:http://dx.doi.org/10.1088/1757-899X/251/1/012067. [19] William G. Foulks, “Historic Building Façades: The Manual for Maintenance and Rehabilitation”, New York Landmarks Conservancy, New York, 1997. [20] Jukka Voutilainen, Methods and Instrumentation for Measuring Moisture in Building Structures, Series E: Electronic Publication E7, Helsinki University of Technology Applied Electronics Laboratory, Finland, 2005. [21] P.K. Larsen, “Moisture measurement in Tirsted Church”, J. Archit. Conserv. 10 (1 March) (2004) 22–35. [22] Tarja Merikallio, Betonirakenteiden kosteusmittaus ja kuivumisen arviointi (Measuring moisture and estimating drying of concrete, in Finnish), Betonikeskus ry, Jyv€askyl€a, Finland, 2002. [23] A. Göller, “Multilayer microwave moisture scans at large areas in civil engineering”, Nondestructive Testing of Materials and Structures. Proceedings of NDTMS-2011 (2013) 793–798. [24] L. Balík, L. Kudrná9cová, Z. Pavlík, R. �Cerný, Application of infrared thermography in complex moisture inspection of the schebek palace. Thermophysics 2017, AIP Conf. Proc. 1866 (2017), doi:http://dx.doi.org/10.1063/1.4994482 40002-1–040002-6. [25] Fray Cipriano Utrera, Santo Domingo: Dilucidaciones históricas (I-II), Publicaciones del Sesquicentenario de la Independencia Nacional, Secretaria de Estado de Educación, Bellas Artes y Cultos, Editora Centenario, Santo Domingo, R.D, 1995, pp. 369. [26] Fray Cipriano Utrera, Noticias Históricas de Santo Domingo, Edición de Emilio Rodríguez demorizi, Volume IV(1979) , pp. 36. [27] Source: Luis Mañon file collection, Archivo General de la Nación, 1947. [28] María Ugarte, Iglesias, Capillas y Ermitas coloniales, Colección Banreservas, Serie Historia, Volume1, Dominican Republic, Santo Domingo, 1995. [29] Virginia Flores, Esteban Prieto, Jose M. Garcia, Characterization of Brick Used in the Cathedral of Santo Domingo, Primate of America, REHABEND: Construction Pathology, Rehabilitation Technology and Heritage Management, Cáceres, Spain, 2018. [30] Source: Dra. Virginia Flores., (2013) . [31] Flores Sasso, Virginia, “El hábitat popular en el entorno del centro histórico. El caso del barrio Santa Bárbara en Santo Domingo”, Segunda Reunión Técnica Académica sobre la Enseñanza y Practica de la Restauración de Sitios y Monumentos, September 2001 Morelia, México, (2001) . [32] Tpi USA. 1010a, Indoor Air Quality Meter. https://www.testproductsintl.com/indoor-air-quality-iaq-2/indoor-air-quality-iaq-meters/1010a-indoor- air-quality-meter/ [accessed 8th April 2018]. [33] Davis Instruments.Vantage Pro2. https://www.davisnet.com/solution/vantage-pro2/ [accessed 2th April 2018]. [34] A. Kylili, P.A. Fokaides, P. Christou, S.A. Kalogirou, Infrared thermography (IRT) applications for building diagnostics: a review, Appl. Energy 134 (2014) 531–549, doi:http://dx.doi.org/10.1016/j.apenergy.2014.08.005 ELSEVIER. [35] G.R. Stockton, After the switchgear, Paper Presented at IR/Info’ 99 (1999). available at: http://www.stocktoninfrared.com/after-the-switchgear/. [36] V.P. Vavilov, A pessimistic view of the energy auditing of building structures with the use of infrared thermography, Russ. J. Nondestr. Test. 46 (12) (2010) 906–910. [37] Raluca Pleşu, Gabriel Teodoriu, George Ú�aranu, Infrared Thermography Applications for Building Investigation, The Bulletin of the Polytechnic Institute of Jassy, Construction. Architecture Section, “Gheorghe Asachi” Technical University of Jassy, T. LVIII, Vol. LXII, No. 1, Romania, 2012, pp. 157–168. [38] UNE-EN 13187:1998 / ISO 6781:1983 modified. “Thermal performance of buildings. Qualitative detection of thermal irregularities in building envelopes. Infrared method”. [39] OMEGA. Table of Total Emissivity. https://www.omega.com/temperature/Z/pdf/z088-089.pdf. [40] TRAMEX Meters, Moisture Detection and Moisture Mapping, Innovation in moisture detection, Ireland, 2017. [41] ] IICRC S500 Standard and Reference Guide for Professional Water Damage Restoration, edition, (2006) . [42] Delmhorst Instrument Co, BD-2100 Owner�s Manual, EEUU, Towaco, 1999. [43] Delmhorst Instrument Co. https://www.delmhorst.com/blog/bid/360520/what-is-a-moisture-meter-reference-scale-and-how-do-i-interpret-it [accessed 27th December 2018]. [44] Golden Software. Surfer Version 15. http://www.goldensoftware.com/products/surfer [accessed 15th April 2018]. |
URI: | https://openarchive.icomos.org/id/eprint/2208 |
Actions (login required)
View Item |
Metadata
- HTML Citation
- ASCII Citation
- Full
- OpenURL ContextObject
- EndNote
- BibTeX
- MODS
- MPEG-21 DIDL
- EP3 XML
- Dublin Core
- Reference Manager
- Eprints Application Profile
- Simple Metadata
- Refer
- METS
Downloads
Downloads per month over past year